3000 psi concrete specifications
INVITATION TO BID# 18015 CONTRACT DOCUMENTS
· to HWWS at the same discounted price structure as the 3000 PSI Ready Mix is at. 2. DESCRIPTION A TWELVE (12) MONTH SUPPLY OF 3000 PSI READY MIX CONCRETE to be furnished under this proposal shall be the type specified. All specifications shown are minimum. There is no intention to disqualify any bidder who can meet the specifications. 3. BID
Concrete SpecificationsDunkStar DIY Basketball Courts
General Concrete Specifications for Basketball and Multi-Game Courts with DunkStar Suspended Surfacing. 4″ Minimum compacted base material to grade. Concrete pad 4″ thick with 6″ thickened edge. 3 000 PSI mix. Light broom finish. Steel reinforcement 3/8″ steel rebar 24 inches to 36 inches on center. Slope/crown 1/2″1″ per 16
3000 psi Concrete RequirementStructural engineering
· The owner received a comment back from the local jurisdiction (King County) that 3000 psi concrete is required in this area of exposed concrete. This will throw the concrete into the inspected range since it is over 2500 psi.
IBC references ACI 318 and ACI 318 requires a minimum of 2 500 psi. See ACI section 5.1.1. The 3 000 psi requirement could possibly be a local ameMike See 2003 IBC Section 1904 and Table 1904.2.2(2). King County WA may be in a moderate or severe exposure region. By this table it would requ1In our area you will not even buy or get 2500 psi concrete unless it is specifically specified in writing. Some lightweight concrete fire protect1I agree with concretemasonry3 000 psi mix is the minimum I use for any structure reinforced or non-reinforced. 2 500 is only used for curbs guI will not argue here but note that Simpson only requires 2500 psi for most of their holddowns but provide tables for strengths in excess of thatConcretemasonry In your area Minnesota I can completely understand that. However our winter weather is much milder here and 2500 psi is regulaMikeThe code is only the least restrictive standard that you can use and be legal but it is not always correct or proper. In our area there isJust wondering if we are becoming "code" engineers or are we "thinking" engineers Do we "follow" the code even if it isn t an absolute necessityMike I think that with the old 97 UBC that we use to spec. 2500 psi concrete to not require Special Inspection on residential projects. Now Secti3000 psi vs 4000 psi concreteACI Appedix D Concrete Pryout Strength D.6.See more results03 05 15PORTLAND CEMENT CONCRETE
· The word "concrete" followed only by a class designation (that is Concrete Class inch) indicates normal weight aggregate concrete such as concrete having a 28-day compressive strength of 3 000 psi a maximum coarse aggregate size of 1 inch and a minimum unit weight of 145 pounds per cubic foot (without reinforcement) at 28 days.
File Size 99KBPORn-AND CEMENT. CONCRETE SECfION
· below 3000 psi Concrete is acceptable. Mix design is rejected. A redesigned mix will be required per #6 below. Moving average is continued. Individual test result between 2850 and 3000 psi. moving average below 3000 psi Concrete may be deemed acceptable. Supplier will be notified that moving average is below 3000 psi.
High Strength Concrete Mix (5000 psi)Vita-Crete
· Ideal for use in cold weather applications. Meets or exceeds the specifications of ASTM C387 for High-early strength concrete. Air entrained version available. COMPRESSIVE STRENGTH 3 days 2500 psi (17.2 MPa) 7 days 3500 psi (24.1 MPa) 28 days 5000 psi (34.5 MPa) Slump Range 2"
DIY Concrete Guide How to order concrete How to
· Concrete specifications consist of Strength (PSI) Slump (basically the thickness) Fiber Mesh Chemical Additives and weather you require a Concrete Pump. 80 of all concrete poured in Florida is 3000 Psi slab mix or 3000 psi pump mix. Other mixes are also available i.e. 3000 Psi5000 Psi mixes Fine Grout C-476 Cell and Flowable Fill.
Specification for Concrete Strength Minimum 4000 psi
· Specification for Concrete Strength Minimum 4000 psiMaximum 5500 psi . A contractor recently called the Hotline about a project specification on which he wanted to bid. The specification required the concrete compressive strength at 28 days to be a minimum of 4000 psi and a maximum of 5500 psi based on the average strength of three
Mechanical Properties of Concrete and Steel
· c = 3 ksi = 3000 psi the tensile strength and modulus of elasticity of concrete are approximated by f = 6 f = 6 (3000) = 330 psi c = 57500 f c = 57500(3000) = 3.15 106 psi If E s = 29 106 psi Modular ratio n = E s /E c 9 Also A g = 10 12 = 120 in2 A = 4
Guide Specification for Controlled Low Strength Materials
· 1 200 psi or less. R3.1 Controlled Low Strength Material (CLSM) While the upper limit on compressive strength is production of structural hydraulic cement concrete. The use of materials not conforming to these standards may be more than suitable or adequate for CLSM mixtures. The specifier however is cautioned to review the
PORn-AND CEMENT. CONCRETE SECfION
· below 3000 psi Concrete is acceptable. Mix design is rejected. A redesigned mix will be required per #6 below. Moving average is continued. Individual test result between 2850 and 3000 psi. moving average below 3000 psi Concrete may be deemed acceptable. Supplier will be notified that moving average is below 3000 psi.
DIVISION 03 00 00. CONCRETEConstruction Contracts
· in accordance with ACI 301 " Specifications for Structural Concrete" and ACI 211.1 " Recommended Practice for Selecting Proportions for Normal Weight Concrete". Concrete slabs patios driveways walls and foundations shall be constructed of a minimum 3000 to 3600 psi concrete 28 day test with a 4" minimum to 6" maximum slump
CONCRETE 101
· difference between a typical 3000 PSI mix and a typical 4000 PSI mix is that there is approximately 100 pounds more of cementious material and approximately 85 pounds less sand in the 4000 pound mix. Cement is the sliding agent in concrete while sand is abrasive which therefore makes the 4000 pound mix pump easier.
DIVISION 03 00 00. CONCRETEConstruction Contracts
· in accordance with ACI 301 " Specifications for Structural Concrete" and ACI 211.1 " Recommended Practice for Selecting Proportions for Normal Weight Concrete". Concrete slabs patios driveways walls and foundations shall be constructed of a minimum 3000 to 3600 psi concrete 28 day test with a 4" minimum to 6" maximum slump
Concrete SpecificationsDunkStar DIY Basketball Courts
General Concrete Specifications for Basketball and Multi-Game Courts with DunkStar Suspended Surfacing 4″ Minimum compacted base material to grade Concrete pad 4″ thick with 6″ thickened edge 3 000 PSI
S-1 (2461) STRUCTURAL CONCRETECONTRACTOR MIX
· concrete for placement in structures pavements and incidental construction. 3000 psi Any # Designates the gradation range for the 4. th. compliance with the Specifications. (3) Allow a maximum of 6 mix designs per concrete grade for a given combination of
Chain Link Fence Specifications
Concrete 3000 PSI . Chain Link Fence Specifications . A chain link fence is a type of woven fence usually made from galvanized steel wire. The chain link fence wire runs vertically and are bent into a zigzag pattern so that each "zig" hooks with the wire immediately on one side and each "zag" with the wire immediately on the other. This forms
SPECIFICATIONSDETAILED PROVISIONS Section 03300
these Specifications as follows except as otherwise specified in the Special Conditions a) Class "AA" 4 000 psi Concrete. Class "M" concrete shall be provided throughout except as specified hereinafter or in the Special Conditions. b) Class "A" 3 000 psi Concrete. Standard Specifications for
Actual Concrete Mix Ratios For 3000 3500 4000 and 4500
A cubic yard of concrete whether it s 3000 psi or 4000 psi weighs about 4000 pounds (when you include the weight of water). But there s 511 pounds of cement used to make 1 yard of 3000 psi concrete and there s 624 pounds of cement used to make 1 yard of 4000 psi concrete.
BuildBlock ICF Concrete Design Mix Specifications
· BuildBlock has listed the met requirements and specifications of their concrete mix. BuildBlock recommends the use of a 3/8″ chip or rock mix 3000 PSI or stronger concrete mix for your walls. Your ready-mix plant will most likely have a mix design
The Strength of Chapter Concrete
· STRENGTH PSI Concrete fill Below 2000 Basement and foundation walls and slabs walks patios steps and stairs 2500–3500 Driveways garage and industrial floor slabs 3000–4000 Reinforced concrete beams slabs columns and walls 3000–7000 Precast and prestressed concrete 4000–7000 High-rise buildings (columns) 10 000–15 000
Everything You Need to Know About Concrete Strength Cor
· The ideal concrete psi for a given project depends on various factors but the bare minimum for any project usually starts around 2 500 to 3 000 psi. Each concrete structure has a normally acceptable psi range. Concrete footings and slabs on grade typically require a concrete of 3 500 to 4 000 psi.
Estimated Reading Time 8 mins3000 psi vs 4000 psi concreteStructural engineering
· RE 3000 psi vs 4000 psi concrete. BAretired (Structural) 6 Aug 15 04 36. I can recall in the early 1950 s when 2000 or 2500 psi concrete was used in suspended slabs and beams. Durability was not considered much in those days and the saving was deemed substantial (at least by some of the contractors with whom I dealt).
Strength of Concrete (PSI) ProMatcher
The strength of concrete is measure in terms of pounds per square inch (or PSI). PSI is a measure of compressive strength or the ability of the material to carry loads and handle compression. 1.) PSI. Most concrete has a PSI rating of 2500 to 3000. This type of concrete can be used for sidewalks and residential driveways.
Code and Standards Requirements For Acceptance Testing
· Series D338 Concrete StrengthHot Weather Exposure 0 1000 2000 3000 4000 5000 6000 0 10 20 30 40 50 60 70 80 90 Age days Compressive Strength psi 60 65 70 75 80 85 Avg. Daily Temp F Standard Curing 48h outmoist Outside Avg daily temp
INVITATION TO BID# 18015 CONTRACT DOCUMENTS
· to HWWS at the same discounted price structure as the 3000 PSI Ready Mix is at. 2. DESCRIPTION A TWELVE (12) MONTH SUPPLY OF 3000 PSI READY MIX CONCRETE to be furnished under this proposal shall be the type specified. All specifications shown are minimum. There is no intention to disqualify any bidder who can meet the specifications. 3. BID
High Strength Concrete Mix (5000 psi)Vita-Crete
· Ideal for use in cold weather applications. Meets or exceeds the specifications of ASTM C387 for High-early strength concrete. Air entrained version available. COMPRESSIVE STRENGTH 3 days 2500 psi (17.2 MPa) 7 days 3500 psi (24.1 MPa) 28 days 5000 psi (34.5 MPa) Slump Range 2"
Specification for Concrete Strength Minimum 4000 psi
· Specification for Concrete Strength Minimum 4000 psiMaximum 5500 psi . A contractor recently called the Hotline about a project specification on which he wanted to bid. The specification required the concrete compressive strength at 28 days to be a minimum of 4000 psi and a maximum of 5500 psi based on the average strength of three
Code and Standards Requirements For Acceptance Testing
· Series D338 Concrete StrengthHot Weather Exposure 0 1000 2000 3000 4000 5000 6000 0 10 20 30 40 50 60 70 80 90 Age days Compressive Strength psi 60 65 70 75 80 85 Avg. Daily Temp F Standard Curing 48h outmoist Outside Avg daily temp
Concrete SpecificationsBabco
6-1/2". 3000 PSI / 28 Day Aging. ACI Temp Only . ACI Temp Only . The floor must be properly aged to American Concrete Institute specifications. The floor does not require reinforcement but a minimum of wire mesh is recommended. Existing concrete floors should be test drilled to verify minimum floor thickness and to confirm building drawings.
3000 psi vs 4000 psi concreteStructural engineering
· RE 3000 psi vs 4000 psi concrete. BAretired (Structural) 6 Aug 15 04 36. I can recall in the early 1950 s when 2000 or 2500 psi concrete was used in suspended slabs and beams. Durability was not considered much in those days and the saving was deemed substantial (at least by some of the contractors with whom I dealt).
PORn-AND CEMENT. CONCRETE SECfION
· below 3000 psi Concrete is acceptable. Mix design is rejected. A redesigned mix will be required per #6 below. Moving average is continued. Individual test result between 2850 and 3000 psi. moving average below 3000 psi Concrete may be deemed acceptable. Supplier will be notified that moving average is below 3000 psi.